A Technical specifications
Version
Comment
Part number 9566945 - NVITE reader
Dimensions 150 x 50 x 40 mm (5.9 x 2 x 1.6 inch)
Color RAL9006 cover and RAL7016 chassis
Weight 0.5 kg (1.1 lbs)
Protection class IP65 (approx. NEMA4x)
Material Aluminum (Zamak5) chassis with polycarbonate cover
Operating temperature -20 to +60 °C (-4 to +140 °F)
Storage temperature -20 to +60 °C (-4 to +140 °F)
Relative humidity 10 to 93 % relative humidity, non-condensing
Power supply 12 to 24 VDC (from power-limited UL294 or UL603 listed power source)
Power consumption 0.4A @ 12 VDC, 0.2A @ 24VDC
Read range
Bluetooth low energy: up to 15 meter (may be restricted by mobile-app)
NFC, LF proximity cards and smartcards: up to 5 cm
Barcode scanner QR-code (QR1, QR2, QR micro), as well as most mainstream 1D and 2D barcodes
Operating frequency
Bluetooth low energy: 2.402 to 2.480 GHz
NFC and smartcards: 13.56 MHz
Proximity cards: 120 kHz
Supported RFID cards
120 kHz: Nedap + EM4200 + HID-PROX + AWID-LF
13.56 MHz: ISO14443A, MIFARE DESFIRE (EV1/EV2), MIFARE Classic, MIFARE
Ultralight (C), MIFARE Plus (SL3), ISO15693, HID iCLASS, LEGIC Advant, LEGIC
Prime and Sony Felica.
Communication interfaces RS485, USB service interface
Communication protocols CR/LF, OSDP
Relay output No relay output
Input 2 TTL digital inputs for LED control, 1 TTL digital input for beeper control
Output
2 open-collector outputs (OSDP)
Wiegand, Magstripe ISO7811/2 (clock & data)
Max. cable length
Fixed cable length of 5 meter (16.4 ft) included pigtail
Wiegand 150 meter (500 ft) 22 AWG
RS485 1200 meter (4000 ft) when installed properly
Tamper switch Magnetic switch, normally closed
Standards
Europe R&TTE Directive 1999/5/EC
USA: FCC Title 47 Part 15B and 15C
Canada: ISED ICES-003 and RSS210
Safety: EN60950-1
EMC: EN301489
Telecom: EN330 330 and EN300 328
Human Exposure assessment: ICNIRP Guidelines, EN62369 and EN50364