Reader function
Select the reader function. This might indicate to the mobile-app the specific function of the reader.
Reader sequence number
Used for reader identification. The sequence number can be any 2 digit hexadecimal number.
Advertising interval
Default advertising interval is 100 msec.
TX power
Set TX power in dBm (default 8 dBm). Not each TX power setting is possible. The value will be rounded to the nearest
possible TX power setting.
It is recommended to keep the highest possible TX power setting. This makes range checking more reliable.
See below the possible TX power settings and the corresponding value (CC) in the Bluetooth device name.
TX power
Range fine tune setting
Bluetooth device name (f CC P NN)
8 dBm
0
f08PNN
6 dBm
0
f06PNN
2 dBm 0
f02PNN
-2 dBm
0
fFEPNN
-7 dBm
0
fF9PNN
-11 dBm
0
fF5PNN
-15 dBm
0
fF1PNN
-19 dBm
0
fEDPNN
8 dBm
Longer +1
f07PNN
8 dBm
Shorter -1
f09PNN