HV Control Panel
17
EN
HV Control Panel
EX
Max Wire Size
(Q1) mm²
Peeling Length =
L(Q1) mm
Max Wire Size
(F7) mm²
Peeling Length =
L (F7) mm
Max Wire Size
(K2) mm²
Peeling Length =
L (K2) mm
EX45kW 4-50 13,5-15,0 16-185 15,0 2,5-50 15,0
EX55kW 10-185 15,0 16-185 15,0 2,5-50 15,0
L
Table5-12:T1PrimaryProteconAutoFuseF2Seng
Type 230V 400V 460V
EX37kW 1,3A 1A 1A
EX45-55kW 1,6A 1,25A 1A
Table5-13:T1SecondaryProtecon(Fuse)Slow
Type F4 Slow F5 Slow F6 Fast
EX37kW Auto6A Auto6A 1A
EX45-55kW Auto6A Auto16A 1A
5.6 Connect Flexlter
Whenallelectricalconneconshavebeenmadefollowthestepsbelowtocompetethe
installaon:
1. Readsecons6.1. Physical buonsand6.2. Display navigaontounderstandhowto
usetheHMI.
2. PresstheHomebuonandthentheSengsbuon.
3. PresseitherVACorRBUtoselectwhichdeviceistobeconnectedtothesystem.
4. UsetheMACROinSystemSetuptocompletetheinstallaonandpreparea
commissioningreport.Seesecon6.10. System setup: MACRO.Seealsosecon
6.12. Commissioning report.