HV Control PanelEN
10
5.3 Electrical installaon
NOTE!
•
Externalemergencystopbuonscanalsobeinstalledifnecessary.
• Thereisalsoanoutputforconnecnganexternalalarmlamp.
• Aachcablestotheproductonlythroughtheglandplateontheboomofthecabinet.
Atdelivery,lookatthenameplatelocatedonthelowerrightsideofthecabinet,andverify
thatthecorrectelectricaldrawingshavebeenprovidedwiththecabinet.
5.3.1 Gather system informaon
Fillinthefollowinginformaon:
• WritetheSerialNumber
Table5-1:Cabinetserialnumber
Cabinet Serial Number Notes
• Verifywhichmainspowersupplieselectricaldata.
Table5-2:Powersupply
Input Volt Mains Fuse Size and Class
Volt Ampere
• VerifyControlcabinetelectricaldata.
Table5-3:Controlcabinetdata
Input Power Supply Control Transformer (T1) (400 V Default)
Volt Volt
• VerifyVAC/RBUelectricalmotordata.
Table5-4:VAC/RBUMotorData
Nominal Voltage Rated load current
Volt Ampere
5.4 System Installaon
NOTE! Allwiresconnectedtopowercomponentsmusthaveendcaps.Itisalways
recommendedthatendcapsareusedonallelectricalwires.
Dimensionthepowercableandmotorcablesaccordingtostandardrules,takinginto
accountcabletypeanddistancetopowersupplyanddistancebetweencontrolcabinetand
motorVAC/RBU.
OnlyconnectcoppercabletotheNedermancontrolcabinetorotherelectricalterminals
suchastheconneconboxontheVAC/RBUmotor.