4 Electric Features and Reliability
4.1 Electric Feature
Table 4-1 Electric feature of the module
Parameter
Minimum Value
Typical Value
Maximum Value
VBAT
Vin
3.4 V
3.9 V
4.3 V
Iin
/
/
2 A
VDDIO_2P8
Vout
/
2.8 V
/
Iout
/
/
50 mA
DIO
Vout
2.3 V
2.8 V
3.1 V
Iout
/
/
4 mA
Vin
-0.3 V
0 V
0.6 V
Iin
/
/
22.5 µA
If the voltage is too low, the module might fail to start. If the voltage is too high or there is a voltage
burst during the startup, the module might be damaged permanently.
If LDO or DC-DC is used to supply power for the module, ensure that it output at least 2 A current.
4.2 Temperature
Table 4-2 Temperature Feature
Module Status
Minimum Value
Typical Value
Maximum Value
Working
-40 °C
25 °C
85 °C
Storage
-45 °C
90 °C

Table of Contents