If the module works in temperature exceeding the thresholds, its RF performance (e.g. frequency
deviation or phase deviation) might be worse but it can still work properly.
4.3 Current
Table 4-3 Current feature
Parameter
Testing Conditions
Testing Result
(Average Current)
Testing voltage
3.9 V Agilent power supply
/
Idle mode
Set the instrument and power on the module.
11 mA
Off leakage current
Power on the module or use AT command to shut
the module down.
170 μA
Average network
searching current
Set the instrument.
Start the module. Wait until the module registers the
instrument.
50 mA
Sleep mode
On a live network, the module registers the network
and then enters the sleep mode.
<2.5 mA
Set the instrument properly (DRX=9)
1.1 mA
Voice service
Maximum power level in full rate
mode
GSM850
194 mA
EGSM900
185 mA
DCS1800
135 mA
PCS1900
126mA
GPRS class 12
4TX, 1RX (4Up/1Down)
GSM850
435 mA
EGSM900
397 mA
DCS1800
268 mA
PCS1900
242 mA
1TX, 4RX (1Up/4Down)
GSM850
184 mA
EGSM900
170 mA
DCS1800
122 mA
PCS1900
117 mA