EasyManuals Logo

Ness D16 Owner's Manual

Ness D16
24 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #13 background imageLoading...
Page #13 background image
NESS D16 CONTROL PANEL - USER MANUAL
13
EXCLUDING ZONES
If a detector becomes faulty and cannot be
Sealed when arming the panel, then its zone
may be Excluded so that it does not generate
alarms.
When zones have been Excluded, the
EXCLUDE light flashes continuously while
the panel is Disarmed and also when Armed.
Zones can only be Excluded when the panel
is Disarmed.
1. Press
[User Code]
...or
(If Exclude Shortcut has been enabled by your installer)
2. (The EXCLUDE light will turn on)
3. Enter the zone number of the zone/s to be Excluded.
[ZONE NUMBER] [ZONE NUMBER] (Up to 16 zones)
The zone light of each Excluded zone will turn on
4. Press to exit Exclude Mode
5. (The EXCLUDE light will flash continuously)
EXCLUDING ZONES
Zone Exclude IS not permanent. Excluded
zones are automatically INCLUDED next time
the panel is Disarmed.
Zones can be manually included by the same
method as Excluding. Simply use the
[ZONE NUMBER] sequence to turn OFF the
zone lights to be Included.
Technical Manuals Online! - http://www.tech-man.com

Other manuals for Ness D16

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ness D16 and is the answer not in the manual?

Ness D16 Specifications

General IconGeneral
BrandNess
ModelD16
CategoryControl Panel
LanguageEnglish

Related product manuals