Transition Networks Contra Converter Quick Setup Guide
Command: Configure CES LAN
Syntax: ces lan setup [ip|udprtp|ethernet] [<mode_no>] [<filter_type>] [ssrc|nossrc]
[<udp_no>] [<ppm_tol>] [lastbyte|fixedbyte] [<bytesused>]
Description: Update the CES network configuration, where:
ip|udprtp|ethernet: Pseudo-wire Protocol Type.
<mode_no> : Clock Recovery Mode (1-3).
<filter_type> : Clock Recovery Filter (1-2).
ssrc|nossrc : Whether to check the SSRC value of received RTP packets.
<udp_no> : UDP Base Port Number (0-65472).
<ppm_tol> : PPM tolerance (5-200).
lastbyte|fixedbyte: Underrun Type.
<bytesused> : Underrun Value.
Example: Configure the CES network configuration:
>ces lan setup ethernet 1 1 ssrc 222 100 lastbyte 99
WARNING
=======
Changes to Protocol Type require the Device to be restarted before the change will take
affect.
CES Global Configuration
========================
Protocol Type : Pseudo-wire over Ethernet
Clock Recovery Mode : Mode 1
Clock Recovery Filter : Type 1
UDP Base Port Number : 222
PPM Tolerance : 100
Underrun Type : Last Byte
>
33604 Rev. A www.transition.com Page 56 of 72