Transition Networks Contra Converter Quick Setup Guide
>ces status clock 2
Clock Recovery Statistics for CLock Stream 2
============================================
00:00 Stream 2 Freerun 0
>
Example 2: Display the current CES Clocking status:
>ces status clock
CES Clocking Status
===================
Lock Mode: Normal
Mode Type: Master
Clock Source: Internal
Stream: 1 status: Freerun mode: 0 (Disabled ) DCO: 0 Recovery inactive
Stream: 2 status: Freerun mode: 0 (Disabled ) DCO: 0 Recovery inactive
Stream: 3 status: Freerun mode: 0 (Disabled ) DCO: 0 Recovery inactive
Stream: 4 status: Freerun mode: 0 (Disabled ) DCO: 0 Recovery inactive
>
Command: Display CES Temperature Status
Syntax: ces status temperature
Description: Show the current temperature of the device and processor.
Example: Display the current temperature status:
>ces status temp
Temperature Status
==================
Type Celsius Fahrenheit
Board Temperature: 47.7 117.8
Processor Temperature: 60.1 140.1
>
33604 Rev. A www.transition.com Page 63 of 72