b. Align both cable chain connectors with their corresponding brackets.
c. Slide the cable chain's horizontal connector under the guide rail on the horizontal bracket and
push it in as far as it will go.
Caution: Risk of equipment malfunction — Make sure to slide the connector underneath
the guide rail on the bracket. If the connector rests on the top of the guide rail, problems
might occur when the system runs.
d. Slide the vertical connector on the right cable chain into the vertical bracket.
e. After you reconnect both ends of the cable chain, carefully pull on the cable chain to verify
that both connectors are latched.
Attention: Risk of equipment malfunction — If the connectors are not latched, the cable
chain might come loose during drawer operation.
4.
Reinstall the right fan module.
5.
Reapply power:
a. Turn on both power switches on the drive shelf.
b. Confirm that both fans come on and that the amber LED on the back of the fans is off.
Replacing a drive drawer in a DS460C disk shelf | 35

Other manuals for NetApp DS224C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NetApp DS224C and is the answer not in the manual?

NetApp DS224C Specifications

General IconGeneral
Form Factor2U
Drive Bays24
Drive Type2.5-inch SAS
Maximum Raw Capacity368 TB
Connectivity12 Gbps SAS
Power SupplyRedundant power supplies
CoolingRedundant fans
Storage TypeHDD and SSD
CompatibilityNetApp FAS and AFF systems

Related product manuals