EasyManua.ls Logo

NetModule NB2800 - Page 35

NetModule NB2800
239 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
NB2800
User Manual for NRSW version 4.5.0.100
Digital Inputs and Outputs (Option 2D)
The isolated input and output ports have the following specification in common:
Feature Specification
Isolation to enclosure/GND 1’500 VDC
Max. cable length 30 m
Cable shield not required
Connector type RJ45
Table 3.35.: Common Digital I/O Specification
The Digital Input signal have the following specification:
Feature Specification
Number of ports 2
Max. input voltage 60 VDC
Max. input current 2 mA
Reverse polarity protection Yes
Min. voltage for Level 1 (set) 7.2 VDC
Max. voltage for level 0 (not set) 5.0 VDC
Table 3.36.: Isolated Digital Input Specification
Note: A negative input voltage is not recognized.
35