75NIBE BA-SVM 10-200 Section 13 | Technical data
Model AMS10-8 + BA-SVM 10-200/12 E/EM/R
Type of heat pump
Air-water
Exhaust-water
Brine-water
Water-water
Low-temperature heat pump
Yes No
Integrated immersion heater for additional heat
Yes No
Heat pump combination heater
Yes No
Climate
Average Cold Warm
Temperature application
Average (55°C) Low (35°C)
Applied standards EN14825 / EN16147
Rated heat output
Prated 7. 0 kW
Seasonal space heating energy efficiency
η
S
127 %
Declared capacity for space heating at part load and at outdoor temperature
Tj
Declared coefficient of performance for space heating at part load and at
outdoor temperature Tj
Tj=-7°C Pdh 6.3 kW Tj=-7°C Pdh 1.94 -
Tj=+2°C Pdh 3.9 kW Tj=+2°C Pdh 3.11 -
Tj=+7°C Pdh 2.6 kW Tj=+7°C Pdh 4.42 -
Tj=+12°C Pdh 3.7 kW Tj=+12°C Pdh 5.93 -
Tj=biv Pdh 6.6 kW Tj=biv Pdh 1.83 -
Tj=TOL Pdh 5.9 kW Tj=TOL Pdh 1.86 -
Tj=-15°C(ifTOL<-20°C) Pdh kW Tj=-15°C(ifTOL<-20°C) Pdh -
Bivalent temperature T
biv
-8.6 °C Min. outdoor air temperature TOL -10 °C
Cycling interval capacity Pcych kW Cycling interval efficiency COPcyc -
Degradation coefficient Cdh 0.97 - Max supply temperature WTOL 58 °C
Power consumption in modes other than active mode Additional heat
Off mode P
OFF
0.002 kW Rated heat output Psup 1. 1 kW
Thermostat-off mode P
TO
0.010 kW
Standby mode P
SB
0.015 kW Type of energy input Electric
Crankcase heater mode P
CK
0.030 kW
Other items
Capacity control Variable Rated airflow (air-water) 3 000 m
3
/h
Sound power level, indoors/outdoors L
WA
35 / 55 dB Rated heating medium flow 0.60 m
3
/h
Annual energy consumption
Q
HE
4 447 kWh
Brine flow rate in brine-water or water-water
heat pumps
m
3
/h