12 PELLUX 100/20 TOUCH
PELLUX 100/30 TOUCH
EN
Hot Water
Buffer
Alarm history
Menu level (PIN)
Solar heating (requires extension module)
Return
Return
Alarm
conrmation
Return
Circulating
pump
Return
Supply
temp.
Return
temp.
Settings
Settings
Settings
Heating power
Temp. max
[TOP]
Temp. max
[BOTTOM]
Current DHW temp
Current temp., BOTTOM
Current temp., TOP
Current DHW temp
The HOT WATER submenu shows the current domes-
tic hot water temperature set point, preset programme
and operating mode. After pressing the SETTINGS
button, you enter the following HOT WATER settings:
• Comfort temperature [�C] - DHW temperature
set point in the comfort interval in the Time mode
or in the Comfort mode.
• Economical temperature [�C] - DHW tempera-
ture set point in the economic interval in the Time
mode or in the Economic mode.
• Heat now - Activates one-off DHW heating to the
comfort temperature regardless of the preset pro-
gramme.
• Histeresis [�C] - DHW heating will start, when
the temperature in the tank is lower than the pre-
set one, decreased of hysteresis.
• Antilegionella - activates the function of periodic
heating of the tank up to 60 °C, which reduces
the risk of developing Legionella bacteria. The
heating starts on Wednesday night at 1:00 am.
• Hot water priority - DHW priority for a given CH
circuit. When heating DHW, HC pump does not op-
erate.
The SOLAR HEATING submenu presents the cur-
rent status of the solar heating system operation, the
supply and return temperatures as well as the current
heating power. After pressing the SETTINGS button,
you enter the following solar heating settings:
The BUFFER submenu shows the current buffer tem-
perature in its upper and lower parts. After pressing
the SETTINGS button, you enter the following buffer
settings:
• Min. temp. (top) [�C] - the charging process in the
upper part of the buffer begins below this temperature.
• Max. temp. (bottom) [�C] - the charging process in
the lower part of the buffer ends up above this tem-
perature.
The last 20 alarms that have been detected by the
controller are shown in the Alarm history submenu.
You have to acknowledge the currently present alarm
in the alarm history in order to switch off the alarm
sound.
This function is intended for service technicians. In
order to increase the menu level, enter the appropri-
ate PIN code and then conrm it with the OK button.
• Flow [l/min] - uid ow through the solar heating
system during the pump operation. The param-
eter is needed to calculate the collector power .
• Delta switch on [�C] - temperature difference
between the collector and the heated water need-
ed to start the solar heating pump.
• Delta switch off [�C] - temperature difference
between the collector and the heated water need-
ed to stop the solar heating pump.
• Temp. HC for - 20�C [�C] - system temperature
set point, when the outside temperature is -20�C.
• Temp. HC for -10�C [�C] - system temperature
set point, when the outside temperature is -10�C.
• Temp. HC for 0�C [�C] - system temperature set
point, when the outside temperature is 0�C.
Schedule
Operating
mode
Section 5 | First Start-Up & Operation of the Boiler