Technical Data
Technical Data
Height 2095 mm
Required ceiling height 2197 mm
Width 600 mm
Depth 640 mm
Net weight 210 kg
Volume total 244 litres
Volume boiler section 55 litres
Volume water heater 189 litres
Volume, expansion vessel 10 litres
Supply voltage 400 V ~ 3-phase + N
Output immersion heater 9,0 kW (connected on delivery 8.0 kW)
Rated output, circulation pump 100 W (adjustable)
Driving power fan (DC) 25-140 W
Rated output, compressor 1,0 kW
Enclosure class IP 21
Max pressure in storage heater 0,9 MPa (9 bar)
Max pressure in boiler section 0,25 MPa (2.5 bar)
Breaking value, high pressure pressostat 2,45 MPa (24.5 bar)
Breaking value, low pressure pressostat 0,15 MPa (1.5 bar)
Fuse pressure in boiler section 0,25 MPa (2.5 bar)
Refrigerant volume 380 g
Refrigerant type R 290 (propane)
Sound level in the heat pump room 40-45 dBA
Room thermostat RT 10
A room thermostat can be installed to stop
heat production at high room temperatu-
res.
Art nr 418 366
Bracket pack
Wall mounting of exhaust air section.
Art nr 089 304
Enclosed kit
Accessories
Outdoor sensor
Load monitor EBV 112
With temporary high current drain the load monitor
disables parts of FIGHTER 640p’s electrical output to pro-
tect the building’s main fuses.
Art nr 418 121
Splitter kit DS 11
Used if the heat pump is to be split up and the modules
each placed individually. Contains splitter wiring, pipe con-
nections, hoses for condensation water and evacuation as
well as top panel for heater section.
Art nr 089 661