EasyManuals Logo

Nidec 5200250 User Manual

Nidec 5200250
124 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #104 background imageLoading...
Page #104 background image
104 Unidrive M / HS Frame 7 to 10 Power Installation Guide
This is the limit for broad-band (random) vibration. Narrow-band vibration at this level which
coincides with a structural resonance could result in premature failure.
Bump Test
Testing in each of three mutually perpendicular axes in turn.
Referenced standard:IEC 60068-2-29: Test Eb:
Severity: 18 g, 6 ms, half sine
No. of Bumps: 600 (100 in each direction of each axis)
Random Vibration Test
Testing in each of three mutually perpendicular axes in turn.
Referenced standard:IEC 60068-2-64: Test Fh:
Severity: 1.0 m²/s³ (0.01 g²/Hz) ASD from 5 to 20 Hz
-3 dB/octave from 20 to 200 Hz
Duration: 30 minutes in each of 3 mutually perpendicular axes.
Sinusoidal Vibration Test
Testing in each of three mutually perpendicular axes in turn.
Referenced standard: IEC 60068-2-6: Test Fc:
Frequency range: 5 to 500 Hz
Severity: 3.5 mm peak displacement from 5 to 9 Hz
10 m/s² peak acceleration from 9 to 200 Hz
15 m/s² peak acceleration from 200 to 500 Hz
Sweep rate: 1 octave/minute
Duration: 15 minutes in each of 3 mutually perpendicular axes.
EN 61800-5-1:2007, Section 5.2.6.4. referring to IEC 60068-2-6
Frequency range: 10 to 150 Hz
Amplitude: 10 to 57 Hz at 0.075 mm pk
57 to 150 Hz at 1g p
Sweep rate: 1 octave/minute
Duration: 10 sweep cycles per axis in each of 3 mutually perpendicular axes
5.1.13 Starts per hour
By electronic control: unlimited
By interrupting the AC supply: 20 (equally spaced)
5.1.14 Start up time
This is the time taken from the moment of applying power to the drive, to the drive being ready to run
the motor:
Size 7 to 10: 5s
For faster start up time a 24V backup supply can be used, see section 4.4 24 Vdc supply on page 63
5.1.15 Output frequency / speed range
Unidrive Mxxx models:
In all operating modes (Open loop, RFC-A, RFC-S) the maximum output frequency is limited to 550
Hz.
Unidrive HSxx models:
In open loop mode the maximum achievable output frequency is 3,000 Hz.
In RFC-A and RFC-S modes, the maximum achievable output frequency is 1,250Hz.