50
Emergency mode central heating
If an error occurs in the control system or components in the AIR air/water heat pump, and the heat pump therefore stops, it will not
be able to heat up the house by the central heating.
If the installer is not able to come right away or the error happens outside the opening hours, and you therefore cannot contact the in-
staller, there is a possibility to heat up the house by setting the AIR heat pump into emergency mode.
The button for emergency mode is located
behind the large door.
The emergency mode for supplemental electric heating has three settings:
I - Auto:
The supplemental electric heating is controlled by the unit control system
(standard setting).
0 - Off:
The supplemental electric heating is turned off and cannot by turned on via the unit
control system.
II - Manuel:
The supplemental electric heating is turned on and cannot be turned off via the unit
control system.
The emergency mode for the circulation pump has tree settings:
I - Auto:
The circulation pump is controlled by the unit control system (standard setting).
0 - Off:
The circulation pump is turned off and cannot be turned on via the unit control sys-
tem.
II - Manuel:
The circulation pump is turned on and cannot be turned off via unit control system.
ATTENTION
When the supplemental electric heating is in I or II the circulation pump must be in the same position.
ATTENTION
In manual mode the supply flow temperature can reach 40 °C.