Scrub Motor Turn-Off Delay Adjustment:
FACTORY DEFAULT: 1 (0.5 second)
RANGE: 1 - 9 (0.5 – 4.5 seconds)
The amount of time that the scrub brushes continue to run after the foot pedal returns to neutral is adjustable. To select the desired delay:
1 Turn the main power key switch to the off position.
2 Press and hold the scrub system off switch.
3 While holding the scrub system off switch turn the main power key switch to the on position.
4 Continue to hold the scrub system off switch until all indicators except the scrub off indicator turn off (approximately two seconds).
5 Release the scrub off switch.
6 The status display will now show a number from 1 to 9. Pressing and releasing the scrub off switch will increase the displayed value until
9 is reached. The next press will return to 1. Each increment represents 0.5 second with 1 equal to 0.5 second.
7 To save the new setting, turn the main power key switch to the off position.
8 The new setting will be saved and will remain in effect until it is changed again.
Vacuum Turn-Off Delay Adjustment:
FACTORY DEFAULT: 1 (12 seconds)
RANGE: 1 - 9 (12 – 20 seconds)
The amount of time that the vacuum continues to run after the foot pedal returns to neutral is adjustable. To select the desired delay:
1 Turn the main power key switch to the off position.
2 Press and hold the vacuum/squeegee switch.
3 While holding the vacuum/squeegee switch turn the main power key switch to the on position.
4 Continue to hold the vacuum/squeegee switch until all indicators except the vacuum/squeegee indicator turn off (approximately two
seconds).
5 Release the vacuum/squeegee switch.
6 The status display will now show a number from 1 to 9. Pressing and releasing the vacuum/squeegee switch will increase the displayed
value until 9 is reached. The next press will return to 1. Each increment represents one second with 1 equal to twelve seconds.
7 To save the new setting, turn the main power key switch to the off position.
8 The new setting will be saved and will remain in effect until it is changed again.
Main and Side Broom Turn-Off Delay Adjustment:
FACTORY DEFAULT: 3 (5 seconds)
RANGE: 1 - 9 (3 – 11 seconds)
The amount of time that the main broom and side brooms continue to run after the foot pedal returns to neutral is adjustable. To select the
desired delay:
1 Turn the main power key switch to the off position.
2 Press and hold the side broom up/off switch.
3 While holding the side broom up/off switch turn the main power key switch to the on position.
4 Continue to hold the side broom up/off switch switch until all indicators except the side broom up/off indicator turn off (approximately two
seconds).
5 Release the side broom up/off switch switch.
6 The status display will now show a number from 1 to 9. Pressing and releasing the side broom up/off switch will increase the displayed
value until 9 is reached. The next press will return to 1. Each increment represents one second with 1 equal to three seconds.
7 To save the new setting, turn the main power key switch to the off position.
8 The new setting will be saved and will remain in effect until it is changed again.