SUPER USER KEY (yellow)
The Super User (yellow) key allows you to check some additional information on some machine operating parameters and to adjust
others to your specic requirements.
Main Screen (E, Fig. 7)
1. Insert the Super User (yellow) key in place of the operator
(grey) key to access the main screen of the multifunction
display (51).
2. Press push-button (A) to change the machine settings (see
Machine Settings Screen section).
3. Press push-button (B) to check for any stored machine
alarms (see Alarms Log Screen section).
4. Press push-button (C) to check the machine’s hours of
operation (see Operating Time Counter Screen section).
5. Press push-button (D) to exit service mode and return to
operator mode.
Machine Settings Screen (F, Fig. 7)
This function allows you to customise some parameters
described in the following table of modiable parameters.
1. Press push-button (B) to increase the value of the current
parameter.
Press push-button (C) to decrease the value of the current
parameter.
2. Press push-button (A) to move to the next parameter.
3. To return to the main screen, press and hold the push-
button (A) for more than 1 second.
Figure 7
P100869
TABLE OF MODIFIABLE PARAMETERS Values
Code Description Minimum Factory Setting Maximum
CHM1 Detergent concentration level 1 0.25 % (1:500) 0.25 % (1:500) 3 % (1:33)
CHM2 Detergent concentration level 2 0.25 % (1:500) 0.80 % (1:125) 3 % (1:33)
P1/P3 Level 1 solution ow rate in relation to level 3
(ow rate as function of speed)
0 % 25 % 100 %
P2/P3 Level 2 solution ow rate in relation to level 3
(ow rate as function of speed)
0 % 50 % 100 %
P3 Level 3 solution ow rate (ow rate as function of speed) 1.0 cl/m 3.0 cl/m 5.0 cl/m
P4 Enablement of level 4 (2.8 l/min regardless of speed) OFF OFF ON
SPT EcoFlex™ function timer 0 (disabled) 60 sec. 300 sec.
XPRES Brush deck extra pressure enablement OFF ON ON
FVMAX Maximum forward speed 10 % 100 % 100 %
RVMAX Maximum reverse speed 10 % 40 % 50 %
WSMIN Minimum working speed 10 % 25 % 100 %
WSMAX Maximum working speed 10 % 100 % 100 %
BRK Electromagnetic brake activation delay 0 sec. 1 sec. 5 sec.
BAT (**) Installed battery type (see table) 0 1 5
TOFF Automatic shut-off time 0 (disabled) 300 sec. 600 sec.
BRGH Display contrast 5 15 50
VRID Silent mode setting 1 1 5
RPM (*) Reduced brush rpm activation threshold 5 9 20
RESET Restore factory settings for all parameters OFF OFF ON
(*) Increase the value of this parameter to reduce the brush motor speed in a wider range of applications and vice versa.