System Management
Edition: 01 3HE 16132 AAAB TQZZA 421
The agent periodically takes statistical sample values from the MIB variable specified for
monitoring and compares them to thresholds that have been configured with the alarm
command. The alarm command configures the MIB variable to be monitored, the polling
period (interval), sampling type (absolute or delta value), and rising and falling threshold
parameters. If a sample has crossed a threshold value, the associated event is generated.
The no form of this command removes an rmon-alarm-id from the configuration.
Parameters rmon-alarm-id — Specifies the alarm being configured. The number of alarms that can
be created is limited to 1200.
Values 1 to 65535
variable-oid oid-string — Specifies the variable to be sampled. Only SNMP variables
that resolve to an ASN.1 primitive type of integer (integer, Integer32, Counter32,
Counter64, Gauge, or TimeTicks) may be sampled. The oid-string may be expressed
using either the dotted string notation or as object name plus dotted instance
identifier. For example, "1.3.6.1.2.1.2.2.1.10.184582144" or "ifInOctets.184582144".
The oid-string has a maximum length of 255 characters
interval seconds — Specifies the polling period over which the data is sampled and
compared with the rising and falling thresholds. In the case of delta type sampling,
the interval should be set short enough that the sampled variable is very unlikely to
increase or decrease by more than 2147483647 - 1 during a single sampling interval.
To avoid creating unnecessary processing overhead, the interval value should not be
set too low.
Values 1 to 2147483647
sample-type — Specifies the method of sampling the selected variable and calculating
the value to be compared against the thresholds.
Default absolute
Values absolute — Specifies that the value of the selected variable will be
compared directly with the thresholds at the end of the sampling
interval.
delta — Specifies that the value of the selected variable at the last
sample will be subtracted from the current value, and the difference
compared with the thresholds.
startup-alarm alarm-type — Specifies the alarm that may be sent when this alarm is first
created.
If the first sample is greater than or equal to the rising threshold value an startup-
alarm is equal to rising or
either, a single rising threshold crossing event is
generated.
If the first sample is less than or equal to the falling threshold value and startup-
alarm is equal to falling or either, a single falling threshold crossing event is
generated.
Default either
Values rising, falling, either

Table of Contents

Other manuals for Nokia 7210 SAS-M

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nokia 7210 SAS-M and is the answer not in the manual?

Nokia 7210 SAS-M Specifications

General IconGeneral
BrandNokia
Model7210 SAS-M
CategoryCell Phone
LanguageEnglish

Related product manuals