Context config>system>sync-if-timing
Supported
Platforms
Supported on all 7210 SAS platforms as described in this document, including platforms
configured in the access-uplink operating mode; not supported on 7210 SAS platforms
configured in the standalone-VC operating mode
Description This command discards changes that have been made to the synchronous interface timing
configuration during a session.
begin
Syntax begin
Context config>system>sync-if-timing
Supported
Platforms
Supported on all 7210 SAS platforms as described in this document, including platforms
configured in the access-uplink operating mode; not supported on 7210 SAS platforms
configured in the standalone-VC operating mode
Description This command creates or edits the system synchronous interface timing configuration.
bits1
Syntax bits1
Context config>system>sync-if-timing
Supported
Platforms
7210 SAS-T (network and access-uplink), 7210 SAS-Mxp, 7210 SAS-R6 and
7210 SAS-R12
Description This command enables the context to configure parameters for the Building Integrated Timing
Supply (BITS).
Note:
• The 7210 SAS-R6 supports the configuration of only the BITS1 interface for use as an
input or output reference. The 7210 SAS-R12 has only a single BITS port on the front
panel, unlike the 7210 SAS-R6, which has two ports. Therefore, this command is
invalid for the 7210 SAS-R12.
• The 7210 SAS-T and 7210 SAS-Mxp allow for configuration of both BITS1 and BITS2
interface as an input and output reference.
• On the 7210 SAS-T and 7210 SAS-Mxp, the BITS1 configuration parameters such as
bits-interface-type, line-length, and source-reference are inherited for BITS2 interface.
CLI commands are available that provide the user an option to administratively control
the BITS2 interface, allowing them to shutdown or enable the BITS2 input and output
independently of BITS1 interface. Read the other commands for more information.