3HE 16132 AAAB TQZZA Edition: 01
Description This command describes an alarm contact input pin. The description provides an indication
of the usage or attribute of the pin. It is stored in the CLI configuration file and helps the user
in identifying the purpose of the pin.
normal-state
Syntax normal-state [open | closed]
Context config>system>alarm-contact-input
Supported
Platforms
7210 SAS-M (network and access-uplink), 7210 SAS-T (network and access-uplink),
7210 SAS-Mxp, 7210 SAS-R6 and 7210 SAS-R12
Description This command configures the normal state to be associated with the alarm-contact input.
When the system detects a transition from the normal state, an alarm is generated. The alarm
is cleared when the system detects a transition is back to the normal state.
Parameters open — Specifies an open normal-state. When the system detects a transition to the
closed state, an alarm is generated. The alarm is cleared when the system detects a
transition back to the open state.
closed — Specifies a closed normal-state. When the system detects a transition to the
open state, and alarm is generated. The alarm is cleared when the system detects a
transition back to the closed state.
shutdown
Syntax [no] shutdown
Context config>system>alarm-contact-input
Supported
Platforms
7210 SAS-M (network and access-uplink), 7210 SAS-T (network and access-uplink),
7210 SAS-Mxp, 7210 SAS-R6 and 7210 SAS-R12
Description This command stops tracking the state changes associated with the alarm contact input.The
system does not generate or clear the alarms for the alarm-contact input, but if an alarm is
generated for the alarm-contact-input, the system clears the alarm when the shutdown
command is executed.
The no form of this command starts tracking the state changes associated with the alarm
contact input.
Default shutdown
trigger-alarm-msg
Syntax [no] trigger-alarm-msg {alarm-msg-text}

Table of Contents

Other manuals for Nokia 7210 SAS-M

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nokia 7210 SAS-M and is the answer not in the manual?

Nokia 7210 SAS-M Specifications

General IconGeneral
BrandNokia
Model7210 SAS-M
CategoryCell Phone
LanguageEnglish

Related product manuals