7210 SAS-M, T, R6, R12, Mxp, Sx, S Basic System
Configuration Guide
System Management
Edition: 01 3HE 16132 AAAB TQZZA 485
Context config>system>alarm-contact-input
Supported
Platforms
7210 SAS-M (network and access-uplink), 7210 SAS-T (network and access-uplink),
7210 SAS-Mxp, 7210 SAS-R6 and 7210 SAS-R12
Description This command allows the user to configure a text message for use along with SNMP trap and
Log message that are sent when the system generates an alarm. The system generates a
default message if the message is not configured.
The no form of this command removes the configured alarm trigger message.
Parameters alarm-msg-text — Specifies a printable character string, up to 160 characters.
6.12.2.1.11 Redundancy Commands
redundancy
Syntax redundancy
Context admin
config
Supported
Platforms
7210 SAS-R6, 7210 SAS-R12, 7210 SAS-Sx/S 1/10GE: standalone-VC
Description This command enables the context to configure redundancy operations.
rollback-sync
Syntax rollback-sync
Context admin>redundancy
Supported
Platforms
7210 SAS-R6 and 7210 SAS-R12
Description This command copies the entire set of rollback checkpoint files from the active CPM CF to
the inactive CPM CF.
synchronize
Syntax synchronize {boot-env | config}
Context admin>redundancy