ETSI environmental and CRoHS guidelines
11
Nokia FastMile Outdoor Unit User Manual
3TG-00088-AAAA-TCZZA Issue: 01P03
2.3 Other environmental requirements
Observe the following environmental requirements when handling Nokia FastMile
Outdoor Unit equipment.
2.3.1 Environmental requirements
See chapter 9 in this guide for more information about temperature ranges for the
Nokia FastMile Outdoor Unit equipment and other Nokia FastMile Outdoor Unit
specifications.
2.3.2 Storage
According to ETS 300-019-1-1 - Class 1.1, storage of Nokia FastMile Outdoor Unit
equipment must be in Class 1.1, weather-protected, temperature-controlled
locations.
2.3.3 Transportation
According to EN 300-019-1-2 - Class 2.3, transportation of Nokia FastMile Outdoor
Unit equipment must be in packed, public transportation.
2.3.4 Stationary use
According to EN 300-019-1-3 - Class 3.1/3.2/3.E, stationary use of Nokia FastMile
Outdoor Unit equipment must be in a temperature-controlled location, with no rain
allowed, and with no condensation allowed.
2.3.5 Thermal limitations
The thermal limitations for the Nokia FastMile Outdoor Unit equipment are:
operating temperature (ambient): –30°C to 65°C (–22°F to 149°F)
operating relative humidity: 5% to 85% relative humidity, non-condensing
short-term relative humidity: 5% to 93% relative humidity, non-condensing