EasyManua.ls Logo

NorAM 65 E T4 FINAL - Every 1000 Hours or 1 Year

NorAM 65 E T4 FINAL
196 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
NORAM 65ET GRADER
5-11
Lubrication and Maintenance - Cummins Tier 4 Final
5
Every 1000 Hours or 1 Year
EVERY 1000 HOURS OR 1 YEAR
Radiator Pressure Cap - Check
The cooling system is designed to use a pressure cap (1) to
prevent the coolant from boiling. An incorrect or
malfunctioning cap can result in the loss of coolant and the
engine running hot.
Inspect for Reuse
Ensure the correct radiator cap is being used.
Inspect the rubber seal of the pressure cap for
damage.
Inspect the radiator fill neck for cracks or other
damage.
Pressure test the radiator cap. The pressure cap MUST seal within 2 psi (14 kPa) of the value
stated on the cap, or it MUST be replaced.
Refer to “Cummins QSF3.8 Operation and Maintenance Manual” for complete instructions.
Belt-Driven Fan Hub - Check
Refer to “Cummins QSF3.8 Operation and Maintenance Manual” for instructions.
1