NORAM 65ET GRADER
5-14
When Required
1
5
Lubrication and Maintenance - Cummins Tier 4 Fi-
Air Cleaner Secondary Element - Replace
Change air filter inner element every third time the outer element is changed.
NOTICE: DO NOT clean inner element.
1. Remove air filter outer element and replace, as necessary. Refer to
"Air Filter Outer Element -
Replace", page 5-13.
2. Remove inner element
(1) by pulling on it and
discard.
3. Install new inner element by firmly pressing it into
place. Be sure inner element is seated properly.
4. Install outer element and cover.
Engine - Clean
Steam is the preferable method of cleaning an engine. If steam is not available, use a solvent to clean
the engine.
NOTICE: Protect all electrical components, openings, and wiring from the full force of the cleaner spray
nozzle.
When using a steam cleaner, wear safety glasses or a face shield and
protective clothing. Hot steam can cause serious personal injury.