1
NORAM 65ET GRADER
3-6
Operation
3
Rollover Protective Structure (ROPS)
Machine Shutdown Procedure
Before stopping the engine, idle engine for 3 to 5 minutes
to allow turbocharger and manifold to cool and prevent
possible distortion of components.
To stop engine:
1. Move Transmission Control Lever to NEUTRAL.
2. Apply parking brake.
3. Rotate circle so moldboard is within the width of the
tires. Lower moldboard to the ground.
4. Lower front and rear implements to ground or install
lock pins in raised implements.
5. Idle engine for 3 to 5 minutes.
6. Turn Ignition Key
(1) OFF.
7. Turn Master Switch
(2) OFF.
NOTICE: Disconnecting battery too soon will prevent
purging of the DEF lines after engine is shut down. Damage
to the DEF system and emission control system can occur
NOTICE: If equipped with a CAT engine, DO NOT turn master switch OFF while lamp (3) is illuminated.
Lamp remains ON approximately 2 minutes after engine is shut down.
NOTICE: If equipped with a Cummins engine, DO NOT turn master switch OFF for approximately 2
minutes after engine is shut down.
1
3
2