15
Releasing
1. Fit PneuTorque
®
with the correct size impact or high quality
socket.
2. Ensure the Forward / Reverse collar is correctly set (in for right
hand threads).
3. Rotate tool and reaction arm into a convenient position.
Fit the tool onto the fastener.
Locate reaction arm adjacent to the reaction point.
4. Adopt a suitable posture to counteract normal or unexpected
movement of the tool due to reaction forces.
5. Gently press trigger to bring the reaction arm into contact with the
reaction point.
6. Fully press the trigger and keep fully depressed until fastener releases.
TIP: If unable to release the fastener increase the air pressure to the tool.
Do not use excessive air pressure.
WARNING: EXCEEDING THE MAXIMUM AIR PRESSURE WILL CAUSE OVERLOADING
AND MAY LEAD TO SERIOUS DAMAGE.
7. Remove tool from fastener.
WARNING: CHANGING THE AIR PRESSURE AFTER SETTING THE PRESSURE
REGULATOR WILL CHANGE THE STALL TORQUE VALUE.

Related product manuals