EasyManuals Logo

Norcold N811V SERIES User Manual

Norcold N811V SERIES
30 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #14 background imageLoading...
Page #14 background image
www.norcold.com/cda
14
Refrigerator Service ManualN611v, N811v Models
Fault Codes - cont’d.
Flash Pattern "2" - Power Board detected an internal fault.
To reset fault power refrigerator OFF and back ON.
If problem continues, replace Power Board.
Fault / Flash Pattern 2
Service Error
NOR000127-2A
CODE 2
Power ON indicator light flashes ON two times, OFF for 5-seconds, repeats
Fault / Flash Pattern 3
Open High Limit
Flash Pattern "3" - high limit thermal switch is open. The
thermal switch is mounted to the metal insulation pack above
the burner.
Verify:
Is thermal switch electrically open, i.e. has it tripped?
If no, verify wiring is connected properly. Refer to
"Wiring Pictorial" on page 29 for proper connection.
Contact Customer Service.
NOR000127-3A
CODE 3
Power ON indicator light flashes ON three times, OFF for 5-seconds, repeats
Fault / Flash Pattern 4
AC Relay Error
Flash Pattern "4" - AC heater relay contacts of relay K2, on the
Power Board, are stuck closed.
Replace Power Board
NOR000127-4A
CODE 4
Power ON indicator light flashes ON four times, OFF for 5-seconds, repeats
Flash Pattern "5" - gas valve is “mechanically” stuck open and
subsequently the Power Board has sensed a ame present
when there should not be.
Replace the gas valve
Fault / Flash Pattern 5
Flame On, Should Not Be On
NOR000127-5A
CODE 5
Power ON indicator light flashes ON five times, OFF for 5-seconds, repeats

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Norcold N811V SERIES and is the answer not in the manual?

Norcold N811V SERIES Specifications

General IconGeneral
BrandNorcold
ModelN811V SERIES
CategoryRefrigerator
LanguageEnglish

Related product manuals