www.norcold.com/cda
14
Refrigerator Service ManualN611v, N811v Models
Fault Codes - cont’d.
Flash Pattern "2" - Power Board detected an internal fault.
■ To reset fault power refrigerator OFF and back ON.
■ If problem continues, replace Power Board.
Fault / Flash Pattern 2
Service Error
NOR000127-2A
CODE 2
Power ON indicator light flashes ON two times, OFF for 5-seconds, repeats
Fault / Flash Pattern 3
Open High Limit
Flash Pattern "3" - high limit thermal switch is open. The
thermal switch is mounted to the metal insulation pack above
the burner.
Verify:
• Is thermal switch electrically open, i.e. has it tripped?
• If no, verify wiring is connected properly. Refer to
"Wiring Pictorial" on page 29 for proper connection.
• Contact Customer Service.
NOR000127-3A
CODE 3
Power ON indicator light flashes ON three times, OFF for 5-seconds, repeats
Fault / Flash Pattern 4
AC Relay Error
Flash Pattern "4" - AC heater relay contacts of relay K2, on the
Power Board, are stuck closed.
• Replace Power Board
NOR000127-4A
CODE 4
Power ON indicator light flashes ON four times, OFF for 5-seconds, repeats
Flash Pattern "5" - gas valve is “mechanically” stuck open and
subsequently the Power Board has sensed a fl ame present
when there should not be.
• Replace the gas valve
Fault / Flash Pattern 5
Flame On, Should Not Be On
NOR000127-5A
CODE 5
Power ON indicator light flashes ON five times, OFF for 5-seconds, repeats