Pre-installation
First, unpack the cabinet and check it for any transport damage. Do not use a damaged cabinet.
In the event of damage, please contact the shipping company and make sure that the damage is
noted on the consignment note. Check that you have all the parts on the parts list at the back of
this guide. Contact the vendor in the event of damage or missing parts.
Do not locate the unit directly opposite the door as this can cause condensation on the magnetic
seals.
The unit is fitted with a defrost timer. This ensures automatic defrosting of the evaporator four
times x 30 minutes every 24 hours. Defrost water must be drained to a collection tank, drum or
the like. Can also be connected to a drain NOTE: Remember a water lock if connecting to a drain.
CU-330-Split
Dimensions and technical specications
Evaporator element: The evaporator fan on the cold room side should run constantly (to maintain as
constant a temperature as possible in the cold room).
Condenser element: Compressor and condenser fan are controlled by the thermostat.
Cu-330 cold element
Evaporator element
Cu-330 cold element
Evaporator element
Cu-330/Cu-450 split
3
CU-330 SPLIT
External dimensions, warm element w440 x h290 x d400mm
External dimensions, cold element w550 x h145 x d430mm
Power Max. 330W
Lighting 15W tube
Defrost Automatic
Coolant R134A
Net weight, cold element 7 kg
Net weight, warm element 21.5 kg
Power cable length 2.7m
Compressor Danfoss
Volt/Hz 220-240V AC 50Hz
Capacity Up to 4,500 litres
Thermostat setting 3-12ºC
Ambient temperature 10-27 ºC
Unit cold element installed on wall or in ceiling.
NOTE: Extra drip pans must be ordered for wall mounting.