5 Parameterisation
BU 0280 GB Subject to technical amendments 59
5.2.3 BUS module information parameters, general (P170)
Parameter
{Factory setting}
Setting value / Description / Note Device Supervisor
Parameter
set
P170 ...
... [-01]
... [-02]
Current error
0 ... 9999 Current errror. Further details in Section 0 “Error Messages”.
[-01 ] = Current module error
[-02 ] = Last module error
Possible values:
1000
= EEPROM error
1010
= System bus 24V missing
1020 = System bus timeout (see time in P151)
1030
= System bus OFF
Specific to DeviceNet
5210 = DeviceNet bus off
5211 = Address already allocated
5212 = illegal baud rate
5220 = DeviceNet timeout
P171 ... [-01]
...
... [-03]
Software version/ Revision
0,0 ... 9999.9
{ 0.0 }
This parameter shows the software and revision numbers in the module. Array 03 provides
information about any special versions of the hardware or software A zero stands for the
standard version.
[-01]
= Software version
[-02] = Software revision
[-03] = Special version
P172 Configuration
0 ... 2
{ 0 }
The version can be queried in this parameter.
Possible values:
0= internal module
1= external module
2 = Bus TO via SPI

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nord Drivesystems SK CU4-DEV and is the answer not in the manual?

Nord Drivesystems SK CU4-DEV Specifications

General IconGeneral
BrandNord Drivesystems
ModelSK CU4-DEV
CategoryDC Drives
LanguageEnglish

Related product manuals