NORDAC SK 200E Handbuch
142 Subject to technical alterations BU 0200 GB
5.9 Parameter overview, User settings
(P) Depends on parameter set. These parameters can be set in various ways in the four parameter sets.
[xx]
Array parameter. A parameter can be set in various sub-groups.
S
Supervisor parameter, visibility depends on P003.
Parameter Nr.
[Array]
Name
Factory
setting
Super
visor
Setting after commissioning
P 1 P 2 P 3 P 4
OPERATING DISPLAYS (5.1)
P000 Operating display
P001 Selection display 0
P002 Factor display 1.00 S
P003 Supervisor code 1
1 = S parameters are hidden
4 = all parameters are visible
BASIC PARAMETERS (5.2)
P100 Parameter set 0 S
P101 Copy parameter set 0 S
P102 (P) Acceleration time [s] 2.0
P103 (P) Deceleration time [s] 2.0
P104 (P) Minimum frequency [Hz] 0.0
P105 (P) Maximum frequency [Hz] 50.0
P106 (P) Ramp smoothing [%] 0 S
P107 (P) Brake reaction time [s] 0.00
P108 (P) Disconnection mode 1 S
P109 (P) DC brake current [%] 100 S
P110 (P) DC braking time on [s] 2.0 S
P111 (P) P factor torque limit [%] 100 S
P112 (P) Torque current limit [%] 401 (off) S
P113 (P) Jog frequency [Hz] 0.0 S
P114 (P) Brake ventilation time [s] 0.00 S
P120 [01] Option monitoring - Ext 1 S
P120 [02] Option monitoring - Ext 2 S
P120 [03] Option monitoring - Ext 3 S
P120 [04] Option monitoring - Ext 4 S
MOTOR DATA / CHARACTERISTIC CURVE PARAMETERS (5.3)
P200 (P) Motor list 0
P201 (P) Nominal motor frequency [Hz] 50.0 * S
P202 (P) Nominal speed [rpm] 1385 * S
P203 (P) Nominal motor current [A] 4.8 * S
P204 (P) Nominal motor voltage [V] 230 * S
P205 (P) Nominal power [kW] 1.10 *
P206 (P) Motor cos phi 0.78 * S