Installation
A1-47
E 2000 Nordson Corporation
All rights reserved
41-3000V
Issued 5/00
A3EN-04-[3V-A-AAXP]-12
Follow these guidelines when programming temperature settings:
S Check the Manufacturer’s Safety Data Sheet (MSDS) for the
recommended operating temperature of the adhesive that you
will use.
S For a zone to be on, the operating temperature must be set at
38 _C (100 _F) or higher.
S Set the standby temperature 56 _C (100 _F) lower than the operating
temperature.
S Before programming any temperature settings, make sure that the
overtemperature setpoint is at least 14 _C(25_F) higher than the
highest operating setpoint used. Refer to Table A 1-12,
Feature No. 3.
Use this tip to program temperature settings quickly:
Zone
Procedure
All zones to the same
temperature
Follow the procedure To Program All
Zones to the Same Temperature.
Most zones to the same
temperature
1. First, follow the procedure To
Program All Zones to the Same
Temperature.
2. Then, follow the procedure To
Program Setpoint and Standby
Temperatures Individually to change
the settings that you wish.