Operating Parameters
B-4
Part 1073401_07
E 2021 Nordson Corporation
Standard (contd)
6
Service LED Heater Hours (Noneditable)
Description:
A timer indicates how many more hours the heaters need to remain on
before the service LED illuminates (service required).
Value:
0 hours (disabled) to 9999
Resolution:
1 hour
Default Value:
0
Format:
Use:
The service interval time (parameter 5) must be enabled before this
parameter will work.
Note: Heater hours accumulate whenever the heaters LED is illuminated.
7
Motor Off Delay
Description:
Determines the amount of time the motor will remain on after the
switching device turns off.
Value:
0 to 360 seconds
OR
- - - - (infinite)
Resolution:
seconds
Default Value:
0 seconds
Format:
Use:
This parameter functions only when a switching device (switched
hand-held applicator hose, footswitch, etc.) is connected to the switch
receptacle.
8
Automatic Pump On
Description:
Determines if the pump will turn on automatically when the melter is
ready.
Value:
0 = disabled or 1 = enabled
Resolution:
Default Value:
1 (enabled)
Format:
Use:
If Automatic Pump On is disabled, you must press the pump key to turn
the pump on.
If Automatic Pump On is enabled, the pump will turn on automatically
when the melter is ready.
NOTE: If Automatic Pump On is disabled (0) while the pump is running,
the pump will remain on until the pump key is pressed.

Table of Contents

Other manuals for Nordson DuraBlue D4L

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nordson DuraBlue D4L and is the answer not in the manual?

Nordson DuraBlue D4L Specifications

General IconGeneral
BrandNordson
ModelDuraBlue D4L
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals