Configuration
A 4-9
E 2015 Nordson Corporation
All rights reserved
321222_06
Issued 04/2015
Manual
Table A 4-5 Heating Zone Numbers
(Note A)
Zone Type
INTERNAL HOSE GUN
0 Set All
(Note B)
1 Tank Hose 1 Gun 1
2 Grid Hose 2 Gun 2
3 Hose 3 Gun 3
4 Hose 4 Gun 4
NOTE A: Your processor may be able to control the temperature of
two, four, or six hoses and guns, depending upon the
processor and features you have selected.
B: Use Set All to set all zones to the same temperature. Only
zones that are turned on are affected.
Follow these guidelines when configuring temperature settings:
S Check the Safety Data Sheet (SDS) for the recommended operating
temperature of the adhesive that you will use.
S For a zone to be on, the operating temperature must be set at
38 _C (100 _F) or higher.
S Set the standby temperature 56 _C (100 _F) lower than the operating
temperature.
S Before programming any temperature settings, make sure that the
overtemperature setpoint is at least 14 _C (25 _F) higher than the
highest operating setpoint used. Refer to Table A 4-2, Feature No. 3.
S To reduce static power consumption and material degradation, set the
grid temperature 14 _C (25 _F) less than the reservoir setting.