© 2021 Nordson Corporation
7446567-02
7-2
“Maintenance”
Item Task Compleon Time
Frequency
Weekly Monthly Yearly Cycles
Inlet / Outlet Valve
Manifold
Check for leakage at
the weep ports. If more
than residual leakage is
observed from the weep
ports service the valve
seals.
Inspect: 5 Min.
Replace: 30 – 60 Min.
●
Replace serviceable items
using service kit.
30 – 60 Min. ●
Air Fings and Tubing Check for air leaks 5 Min. ●
Material Fings and
Hoses
Check for material leaks 5 Min. ●
Swivel Assembly
Check for damage and
leakage. Inspect weep
ports. If more than
residual leakage is
observed, or material is
dripping from swivel, a
rebuild is necessary.
Inspect: 5 Min.
Apply Grease: 10 Min.
Replace: 30 – 60 Min.
●
Apply grease into grease
Fing.
Apply Grease: 10 Min. ●
Material Outlet Nozzle
Check for leakage and
ghten any loose valve
mounng screws.
Replace if necessary
Inspect: 5 Min.
Tighten: 5 Min.
Replace: 30 – 60 Min.
●
NOTE: All scheduled maintenance should be visually inspected weekly, unl consumer develops the correct maintenance schedule for a
parcular applicaon. Schedule will vary depending on what material is being used in a parcular applicaon. Always listen for air
leaks, keep work area clean of material, and check with material supplier for specic cleaning procedures for the material being used
in an applicaon.
Table 7-1 Preventative Maintenance Schedule