10
S4BE-048KA SERIES
SUCT.
PRESS.
OUTDOOR TEMPERATURE (°F)
70 75 80 85 90 95 100 105
LIQ.
PRESS.
DIS.
TEMP.
LIQ.
PRESS.
DIS.
TEMP.
LIQ.
PRESS.
DIS.
TEMP.
LIQ.
PRESS.
DIS.
TEMP.
LIQ.
PRESS.
DIS.
TEMP.
LIQ.
PRESS.
DIS.
TEMP.
LIQ.
PRESS.
DIS.
TEMP.
LIQ.
PRESS.
DIS.
TEMP.
128 241 136
130
241 139
264 137
132 242 143
264 141
287 139
134
243 147
265 145
287 143
310 141
136 245 151
266 149
288 147
310 145
333 143
138 267 152
289 150
311 148
333 146
356 144
140 290 154
312 152
334 150
356 148
379 146
142 312 155
334 153
357 151
379 150
402 148
144 313 159 335 157
357 155
380 153
402 151
146 335 160 358 158
380 156
403 155
148 358 162 380 160
403 158
150 381 163 403 161
152 403 165
154
Table 8. Charging Table for 4 Ton Models
S4BE-060KA SERIES
SUCT.
PRESS.
OUTDOOR TEMPERATURE (°F)
70 75 80 85 90 95 100 105
LIQ.
PRESS.
DIS.
TEMP.
LIQ.
PRESS.
DIS.
TEMP.
LIQ.
PRESS.
DIS.
TEMP.
LIQ.
PRESS.
DIS.
TEMP.
LIQ.
PRESS.
DIS.
TEMP.
LIQ.
PRESS.
DIS.
TEMP.
LIQ.
PRESS.
DIS.
TEMP.
LIQ.
PRESS.
DIS.
TEMP.
122 243 133
124
244 136
267 136
126 245 140
268 140
291 139
128
246 143
269 143
292 143
315 143
130 247 147
270 147
293 146
315 146
338 146
132 270 150
293 150
316 150
339 150
362 150
134 294 153
317 153
340 153
363 153
386 153
136 318 156
341 156
364 157
387 157
410 157
138 319 160 341 160
364 160
387 160
410 160
140 342 163 365 163
388 163
411 163
142 366 166 389 166
412 166
144 390 169 412 169
146 413 172
148
Table 9. Charging Table for 5 Ton Models
Shaded boxes indicate flooded conditions.
Rated design values. The suction pressure will vary from design value if indoor air flow, entering dry
bulb, or entering wet bulb temperatures are lower than design.
1. All pressures are listed in psig and all temperatures in ° F
2. Discharge temperatures greater than charted values indicate an undercharged system.
3. In Cooling Mode, suction pressure will be lower than design value if indoor air flow, entering dry bulb, or entering
wet bulb temperatures are lower than design.
4. In Heating Mode, charge should be weighed in. It is strongly recommended to verify charge in cooling mode at
ambient above 70°F.