S4BE-024KA SERIES
SUCT.
PRESS.
OUTDOOR TEMPERATURE (°F)
70 75 80 85 90 95 100 105
LIQ.
PRESS.
DIS.
TEMP.
LIQ.
PRESS.
DIS.
TEMP.
LIQ.
PRESS.
DIS.
TEMP.
LIQ.
PRESS.
DIS.
TEMP.
LIQ.
PRESS.
DIS.
TEMP.
LIQ.
PRESS.
DIS.
TEMP.
LIQ.
PRESS.
DIS.
TEMP.
LIQ.
PRESS.
DIS.
TEMP.
134 248 119
136
249 122
272 123
138 250 125
273 126
295 127
140
251 129
273 129
296 130
319 131
142 252 132
274 132
297 133
319 134
342 135
144 275 135
298 136
320 137
343 138
365 140
146 299 139
321 140
344 141
366 142
389 144
148 322 143
345 144
367 145
390 146
412 148
150 323 146 345 147
368 148
391 149
413 150
152 346 149 369 150
391 152
414 153
154 370 153 392 154
415 156
156 393 157 416 158
158 416 161
160
Table 4. Charging Table for 2 Ton Models
S4BE-030KA SERIES
SUCT.
PRESS.
OUTDOOR TEMPERATURE (°F)
70 75 80 85 90 95 100 105
LIQ.
PRESS.
DIS.
TEMP.
LIQ.
PRESS.
DIS.
TEMP.
LIQ.
PRESS.
DIS.
TEMP.
LIQ.
PRESS.
DIS.
TEMP.
LIQ.
PRESS.
DIS.
TEMP.
LIQ.
PRESS.
DIS.
TEMP.
LIQ.
PRESS.
DIS.
TEMP.
LIQ.
PRESS.
DIS.
TEMP.
128 244 121
130
245 124
267 125
132 245 128
268 128
290 128
134
246 132
269 132
291 132
313 132
136 247 136
269 136
292 135
314 136
337 136
138 270 139
293 139
315 139
337 139
360 139
140 293 143
316 142
338 142
360 142
383 143
142 317 146
339 146
361 146
384 146
406 146
144 317 149 340 149
362 149
384 149
407 149
146 341 152 363 152
385 152
407 152
148 364 155 386 155
408 155
150 387 158 409 158
152 410 161
154
Table 5. Charging Table for 2.5 Ton Models
Shaded boxes indicate flooded conditions.
Rated design values. The suction pressure will vary from design value if indoor air flow, entering dry
bulb, or entering wet bulb temperatures are lower than design.
1. All pressures are listed in psig and all temperatures in ° F
2. Discharge temperatures greater than charted values indicate an undercharged system.
3. In Cooling Mode, suction pressure will be lower than design value if indoor air flow, entering dry bulb, or entering
wet bulb temperatures are lower than design.
4. In Heating Mode, charge should be weighed in. It is strongly recommended to verify charge in cooling mode at
ambient above 70°F.

Other manuals for Nordyne S4BE-018KA Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nordyne S4BE-018KA Series and is the answer not in the manual?

Nordyne S4BE-018KA Series Specifications

General IconGeneral
BrandNordyne
ModelS4BE-018KA Series
CategoryAir Conditioner
LanguageEnglish

Related product manuals