2. About the Appliance
2.1 Items Included
When you open the box, you will nd the
following items with the appliance. Check the box
for each of the following items before installing the
appliance.
Water Heater
Installation &
Operation Manuals
Kit Box
Conversion Kit Spare Parts
GF 200
Installation Manual
Cl
earances [
Dégagements
]
GF 200
COMBI
NA
TION GAS WATER H
EATER
/ CENTRAL AI
R HEATING
*COMBI
NAISON
CH
AUFFEE-EAU I
NSTANTANE / GENERATEUR
D'
AI
R CHAU
D
#####
Mad
e i
n Can
ada
Fab
r
iq
ues
au
Can
ada
Serial
Numb
er:
#####
#####
#####
#####
#####
AIR
FLOW
T
hi
s ap
pl
iance i
s approved fo
r upflow ins
t
allat
i
on
.
Cette fournaise
est
approv
ee pour l'ins
tal
lation
et
circulati
on
d'air ascendente.
Min. clear
ance to combustibl
e con
str
uc
t
i
o
n: (in.) see diagram
.
Degagements
mini
mu
m entre l'appareil et
des c
onstruc
tions
combus
tibl
es
(
PO.)
Vent
clearance to combust
i
b
l
e constru
ction (in.):
0
Degageme
n
t de vent
const
r
uctions
combus
tibles
(
PO.): 0
* Mi
n ser
vice clearance
* Degagement
min. pour f
ins
d'entretien pour
les
ins
tallati
ons
C: C
O
M
BUSTIBLE FLOORS
Ref
er to Installati
on
Manual
for s
ervic
e c
lear
anc
e details
0
0
0
0
24*
C
Electrical R
ating /
Caracter
is
tique Elec
trique
VOLTS
FREQ.
PHASE
MCA
MAX.
C
K
T. BRK
INDOOR
BLOW
ER MOT
OR
1
206
0 Hz
1
13 A
9.
6 A
3/4
FLA
HP
C
e
rti
fie
d b
y
Ce
rtif
ie p
ar
NY Ther
mal
Inc
. 30
St
one
ga
te Dr., Sain
t John
, NB,
E
2H 0
A4
, Can
ada
Model
[Modele]
F
ue
l
[
Gaz]
Altitude,
f
t
[Alt
itude,
pi]
Input
,
MBH
[Ent
r
ée,
kW]
Mi
n
Max
Space Heating
Capa
city, MBH
[
Capac
ite de
Chauf
fage,
kW]
Nat.
19.
9 [5.83]200 [58.61]
0 - 4500*
TGF
-200
LP
DHW Heating
Capacit
y, MBH
[Capacit
e de DHW
Chauf
fage, k
W
]
80 [23.
45]
200 [58.61]
FACTORY SET
F
OR NATURAL GAS
Field c
onver
ted
to
Pr
opane Gas
C
O
NFIGURÉE A L'USI
NE POUR GAZ NATU
REL
Conver
t
ie au propane sur place
Date:____________________
____________
Date:
________________________________
G
as Pressure
[Pres
sion du Gaz
]
Natural
[Naturel
]Pro
pane
Maxi
mum Inlet G
as
Pr
essu
re [Pression
maxi
male d'entrée du gaz]
Mi
n
i
mum Inlet G
as
Pr
essu
re
[Pres
sion minimum
d'entr
ée
du gaz]
Manifold Pressure [Pres
sion d'
admis
sion]
10.5" WC
3.5" WC
-0.58" WC
13"
W
C
8" WC
-
0.02 /
-
0.78"
WC
Important Infor
mation
[R
ensignesments
Importants]
U
se
for Natur
al or
LP Gas
only.
Maximum Water Pr
ess
ure
= 150 psi
Max
imum
Stat
ic Pres
sure = 0.8 I
N.
W
.C.
Maximum Inlet
W
ater
T
emperatur
e = 180°
F
This
appli
anc
e m
ust
be ins
tall
ed in
acc
ordance
wi
th l
ocal codes,
if any;
if not
, follow ANSI
Z223.
1/NFPA 54 or CAN/C
SA B149.1,
N
atural
Gas
and Propane I
nst
allation C
ode,
as
applic
able.
U
tili
sez
des gaz
Natur
el ou LP seulement.
Pr
essi
on d'eau max.
= 150 l
b/po²
Pression s
tat
ique max.
= 0.
8 PO. D'
EAU
Temp
. maximale d'
eau d'entrée = 180°
F
Cet appar
eil doit
être ins
tall
é c
onf
ormément
aux
codes
locaux
,
le c
as
éc
héant
; s
inon,
suiv
ez
ANSI
Z223.1 /
NF
PA
54 ou CAN /
CSA B149.1,
gaz natur
el et
propane
Code
d'ins
tall
ation,
le
cas
éc
héant.
F
OR
YOUR SAFETY
Do not
stor
e or
use gasol
ine or othe
r
fl
ammable vapor
s
and l
iquids
in
the vic
init
y
of
this
or any
other appliance.
PO
U
R VOTRE
SÉCURITÉ
Ne pas ent
r
eposer ou utilis
er d'essence ou d'
autres
vapeurs et li
qui
des
inflammables à proximité de c
et
appar
eil ou de
tout autre
appareil.
Standard ANSI
Z
21.
10.
3 /
CSA
4.
3
Gas
W
ater Heaters,
Volume
III St
orage Wat
er
Heater
s
, with
Input
Ratings
Abov
e 75,000 BTU
per Hour, Circulati
ng
and I
nst
ant
aneous
CSA
C22.2
No. 236 / UL 1995
Heating and Cooli
ng
Equipment
*
Refer
to
wate
r
h
eat
er rati
ng
pla
te u
nde
r a
cc
ess p
ane
l o
n th
e o
ppo
si
te s
ide
of
thi
s c
abi
ne
t.
Ori
fices
nec
es
s
ar
y
for LP
co
nv
ersio
n a
r
e
pr
o
vi
ded
.
F
a
ilu
r
e
to u
se
the
c
o
rr
ect ga
s can
c
a
us
e p
rob
le
ms
whi
ch
c
an
resu
lt i
n d
eath
, s
eriou
s i
nju
ry or
pr
ope
rt
y
da
mage
Le
s i
nje
ctu
re
s
n
ec
es
s
ai
res a
la
con
ve
rs
ion
au
GPL
son
t
fou
rn
is.
Le
fa
it d
e ne
pa
s
u
til
ise
r
l
e b
on g
az
pe
ut cau
s
e
r de
s
pr
obl
emes
qu
i p
euv
en
t men
er a l
a mo
rt,
ca
use
r d
es
bes
s
u
r
e
s
gr
av
es ou
end
ommag
er
la
pro
pr
iete
24*
24*
Water he
ater rat
ing pl
ate l
o
cated
un
der access panel
on opposite
side
of
cab
i
net.
20 A
GF 200 Installation
Manual
2.2 Accessories
The following optional accessories are available for
the appliance:
Remote Controller
3 in Vent Termination
Caps
3 in Wall Flanges
4
KIT BOX

Related product manuals