EasyManua.ls Logo

NTI GF 200 - Technical Specifications Table

NTI GF 200
40 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2.3 Specications
The following table lists the specications for the appliance. Additional specications about water, gas,
electric, and air supplies (venting) appear in the Installation section.
Item GF 200
Heat
Capacity
(Input)
Natural Gas
Space Heating:
19,900 – 80,000 BTU/H
DHW Heating:
19,900 – 199,000 BTU/H
Propane Gas
Energy
Factor
UEF (for NG & LP) 0.96
EF (Canada) (for NG &
LP)
0.97
Flow Rate
(DHW)
35 °F (19 °C) Temp Rise 11.2 GPM (42 L/m)
45 °F (25 °C) Temp Rise 8.7 GPM (33 L/m)
67 °F (36 °C) Temp Rise 5.6 GPM (21 L/m)
Dimensions 17.75 in (W) x 38.0 in (H) x 40.0 in (D)
Weight 248 lbs
Installation Type Indoor
Venting Type Forced Draft Direct Vent
Ignition Electronic Ignition
Water Pressure 15 – 150 PSI
Natural Gas Supply Pressure
(from source)
See Water Heater Installation Manual (Supplied)
Propane Gas Supply Pressure
(from source)
Natural Gas Manifold Pressure
(min-max)
Propane Gas Manifold Pressure
(min-max)
Minimum Flow Rate*
0.5 GPM (1.9 L/m), < 0.01 GPM (0.04 L/m) with optional recirculation
mode.
Connection
Sizes
Cold Water Inlet
3
/
4
in sweat joint
Hot Water Outlet
3
/
4
in sweat joint
Gas Inlet
3
/
4
in NPT
Power Supply
Main Supply 120 V AC, 60 Hz
Materials
Casing Cold Rolled Carbon Steel
Heat Exchangers
Primary Heat Exchanger: Stainless Steel
Secondary Heat Exchanger: Stainless Steel
Venting
Exhaust**
See Water Heater Installation Manual (Supplied)Intake
Vent Clearances
Safety
Devices
Flame Rod, APS, Ignition Operation Detector, Water Temperature High Limit Switch, Exhaust
Temperature High Limit Sensor, Power Surge Fuse
*Energy consumption will increase when the system is congured for recirculation.
**High temperature venting material may be required. See section 3.5 Venting the appliance for details.