54 Océ 7050/7051 User Manual
Safety data sheet Océ 7050/7051
©1997 Océ-Technologies B.V.
The content of this safety data sheet is subject to the disclaimer of liability on
page 53 of this manual.
Océ-(UK), Ltd
Langston Road telephone 0181.508.5544
Loughton, Essex IG10 3SL fax 0181.508.6689 Number: E-647-b-UK
United Kingdom Date: May 1995
Model Océ 7050/7051
Description Plain paper engineering (large format) copier , desk-top or console model
Max. process speed 3 m/min
incl. stand incl. shelves incl. man. roll
Dimensions Width 1352 mm 1352 mm 1352 mm 1352 mm
Depth 795 mm 795 mm 795 mm 918 mm
Height 400 mm 1251 mm 1251 mm 1251 mm
Weight 85 kg 114 kg 127 kg 142 kg
Voltage 230 V
Frequency 50 Hz
Current - rated 7,5 A
Current - max 10 A
Power consumption, operation 1500 W
Power consumption, standby 10 W
Mains connection Cable with plug
Safety class I (IEC 536) Protective earth connection
Protection class IP 20 (IEC 529)
Sound pressure level At operator position: in operation 58 dB(A); impulse ∆ L
i
= 3 dB(A)
Sound power level In operation 65 dB(A)
Radio interference Complies with Directive 89/336/EEC
Radiation Below the Threshold Limit V alue for UV radiation (TL V list of ACGIH)
Heat emission Standby 10 W ; in operation 1500 W
Ozone emission 0,04 mg/min at continuous operation
Room volume Recommendation: min. 25 m
3
Room ventilation Recommendation: min. 12,5 m
3
/h (natural ventilation)
Use simulation at random
operation
Room volume and ventilation as recommended
Daily copy volume (much more than average ) 100 m
Total worktime 8 h
Ozone concentrations:
- Time weighted average 0,002 mg/m
3
(0,001 ppm)
- Peak 0,008 mg/m
3
(0,004 ppm)
Threshold Limit V alue/Occupational Exposure Limit
(Time W eighted A verage) for ozone 0,2 mg/m
3
(0,1 ppm)
Odour Perception Limit for ozone 0,04 mg/m
3
(0,02 ppm)
Consumables Océ OPC Drum (Océ Safety Data Sheet E-192)
Océ B1 T oner (Océ Safety Data Sheet E-180)
Océ D1 Developer (Océ Safety Data Sheet E-181)
Océ Copying Materials
Marking CE-Compliance Approved according to Approved according to
Low V oltage Directive EMC Directive
73/23/EEC 89/336/EEC
Additional safety information During the projected lifetime of the copier , the ozone concentration in the workplace will not
exceed 0,04 mg/m
3
Therefore, replacement of the ozone filter will not be necessary