Table of Contents

Other manuals for OHAUS PR423/E

Questions and Answers

  • R
    Ryan NelsonAug 17, 2025
    What does Err 9.5 mean on OHAUS Laboratory Equipment?
    • D
      Daniel LaneAug 17, 2025
      If your OHAUS Laboratory Equipment is displaying 'Err 9.5', the loadcell may not be working correctly.
  • R
    Randall HodgesAug 20, 2025
    What does Err 53 mean on OHAUS Laboratory Equipment?
    • O
      olsenmichaelAug 20, 2025
      If your OHAUS Laboratory Equipment shows 'Err 53', it means there is an issue with the EEPROM.
  • M
    martinezshannonAug 22, 2025
    Why does my OHAUS Laboratory Equipment show '--NO--' when taring?
    • S
      Scott WalshAug 22, 2025
      The '--NO--' error on your OHAUS Laboratory Equipment indicates that the tare is out of range.
  • D
    Dalton EdwardsAug 25, 2025
    Why does my OHAUS Laboratory Equipment show '--NO--' when zeroing?
    • P
      Peggy SmithAug 26, 2025
      The '--NO--' error on your OHAUS Laboratory Equipment indicates that the zero is out of range.
  • A
    abrownAug 28, 2025
    What does 'LoW.rEF' mean on OHAUS Laboratory Equipment?
    • T
      Teresa Shaffer MDAug 28, 2025
      The 'LoW.rEF' error on your OHAUS Laboratory Equipment means that the reference weight is low, and this only applies in counting mode.
  • J
    Jacob ShieldsAug 30, 2025
    What does Err 8.1 mean on OHAUS Laboratory Equipment?
    • P
      Paul PattersonAug 30, 2025
      The 'Err 8.1' error on your OHAUS Laboratory Equipment indicates an over init zero range.
  • R
    Rodney HowardSep 2, 2025
    What does Err 8.2 mean on OHAUS Laboratory Equipment?
    • R
      Rose TravisSep 2, 2025
      The 'Err 8.2' error on your OHAUS Laboratory Equipment indicates an under init zero range.
  • J
    John MossSep 5, 2025
    What does IDnr.Err mean on OHAUS Laboratory Equipment?
    • A
      Anna FosterSep 5, 2025
      The 'IDnr.Err' error on your OHAUS Laboratory Equipment indicates an IDNR error.
  • S
    Sharon RaymondSep 8, 2025
    What does PUSH.LFt mean on OHAUS Laboratory Equipment?
    • B
      Barbara RodriguezSep 8, 2025
      The 'PUSH.LFt' message on your OHAUS Laboratory Equipment indicates that you need to push the LFT button, specifically for PR.
  • V
    Veronica GardnerSep 12, 2025
    What does 'No CAL' mean on OHAUS Laboratory Equipment?
    • J
      Justin SmithSep 12, 2025
      The 'No CAL' error on your OHAUS Laboratory Equipment indicates a production calibration failure.

Summary

Introduction to PR Series Balances

Safety Precautions

Essential safety guidelines before operation.

Installation Guide

Operation and Functionality

Applications

Parts Counting Functionality

Introduction to the parts counting application.

Menu Settings

Calibration Methods Overview

Overview of different calibration methods available.

Balance Setup Options

Customizing various balance functionalities.

Factory Reset and Lockout

Restoring settings and securing menus.

Legal for Trade (LFT) Compliance

Device Sealing Process

Steps to seal the device to prevent tampering.

Printing and Data Output

Maintenance and Troubleshooting

Troubleshooting Common Issues

Table of common issues and their solutions.

OHAUS PR423/E Specifications

General IconGeneral
Capacity420 g
Readability0.001 g
DisplayLCD
Linearity±0.002 g
Stabilization Time2 seconds
CalibrationExternal Calibration
InterfaceRS232
Repeatability0.001 g
Operating Temperature Range10°C – 40°C
Units of Measurementg, oz
Power SupplyAC Adapter or Rechargeable Battery