4. ADJUSTMENT
43984801TH Rev.1
78 /
Oki Data CONFIDENTIAL
Category (1st Line)
(16 Characters)
Item (1st Line)
(16 Characters)
Value
(2nd Line)
Default Function Valid Save
CH V ADJ -5
-4
-3
-2
-1
0
+1
+2
+3
+4
+5
*
In this printer, this setting is not used.
- -
CH V MAX -2
-1
0
*
Maximum CH voltage offset
- -
CH V MIN -1
0
+1
+2
*
Minimum CH voltage offset
- -
TR1 CRNT -3
-2
-1
0
+1
+2
+3
*
Current value converting of TR1_I at TR
resist lead
- -
0X MODE ENABLE
DISABLE
*
[
A/C Zero Cross Phase Control
ENABLE/DISABLE
]
Select whether operate phase control.
- -
0X TC
AUTO
FIX
*
[
TC Fixed/Varied selection
]
Select Tc value (Zero cross signal
period) that is used for parameter
calculating of phase control.
- -
0X TP AUTO
FIX
*
[
TP Fixed/Varied selection
]
Select Tp value (Zero cross signal
pulse width) that is used for parameter
calculating of phase control.
TC varied mode: Use calculated value
TP fixed mode: Use fixed value (1ms)
- -