ETUP
ITEM SETTINGS EXPLANATION
NEARLIFE STATUS ENABLE
DISABLE
Set LCD panel control at the time of near-life
warning for drum.
Enable: Display a near-life warning.
Disable: Do not display a near-life warning.
NEARLIFE LED ENABLE
DISABLE
Enables/disables illumination of front panel LED
when “near-end-of-life” warning of a toner or
drumoccurs.
Attention LED is lit when setting is enabled,
inhibited when disabled.
ITEM SETTINGS EXPLANATION
AUTO PW OFF ENABLE
AUTO CONFIG
DISABLE
Sets the Auto Power Off operation.
ENABLE: When the printer is not used for a
period of time, it turns off the power
automatically.
AUTO CONFIG: Auto power off is enabled,
however, the printer will not turn off the power
under the following conditions:
> An Ethernet cable is plugged to the network
interface connection.
Note: The default setting varies depending on the
sales area.
POWER RETURN MANUAL
STATE
CONTINUE
Set the power on method after energize.
ITEM SETTINGS EXPLANATION
UNIT OF MEASURE INCH
MILLIMETER
Selects the unit of measure.
Note: The default setting varies depending on the
sales area.
DEFAULT PAPERSIZE A4
LETTER
Set default paper size.
Note: The default setting varies depending on the
sales area.