Menu functions > 23
FX E
MULATION
This menu controls the printer’s FX emulation.
P
ARALLEL
MENU
This menu controls the operation of the printer’s parallel data interface.
ITEM DEFAULT REMARKS
CHARACTER PITCH 10 CPI Specifies character pitch in this emulation.
CHARACTER SET SET-2 Specifies a character set.
SYMBOL SET IBM-437 Specifies a symbol set.
LETTER O STYLE DISABLE Specifies the style that replaces 9BH with letter o and 9DH
with a zero
ZERO CHARACTER NORMAL Sets the zero to be slashed or unslashed.
LINE PITCH 6 LPI Specifies the line spacing.
WHITE PAGE SKIP OFF Selects whether blank pages are printed or not.
CR FUNCTION CR Selects whether a received carriage return character (0Dh)
also causes a line feed.
LINE LENGTH 80 COLUMN Specifies the number of characters per line.
FORM LENGTH 11.7 INCH Specifies the length of paper.
TOF POSITION 0.0INCH Specifies the distance of print from the top edge of the
paper.
LEFT MARGIN 0.0INCH Specifies the distance of print from the left hand edge of the
paper.
FIT TO LETTER DISABLE Sets the printing mode that can fit print data, equivalent to
11 inches (66 lines), in the LETTER-size printable area.
TEXT HEIGHT SAME Sets the height of a character.
SAME: Regardless of CPI, same height
DIFF: As CPI, character heights vary.
CONT PAPER MODE OFF Sets printer for using continuous feed stationery.
ITEM DEFAULT REMARKS
PARALLEL DISABLE
Enables or disables the parallel port.
1
1. If the centronics (parallel) port is enabled, the product is no longer Energy Star compliant.
BI-DIRECTION ENABLE ENABLE/DISABLE the bi-directional capability of the
parallel interface.
ECP ENABLE Extended Capabilities Port, enables/disables this function.
ACK WIDTH NARROW Sets ACK width for compatible reception.
ACK/BUSY TIMING ACK IN BUSY Sets the order to output the BUSY and ACK signal for
compatible reception.
I-PRIME DISABLE Sets time to enable/disable I-prime signal
OFFLINE RECEIVE DISABLE To Enable/disable of this function. When set to Enable, the
interface retains a receive possible state even when
switching to Offline. Interface sends the BUSY signal only
when the receive buffer is full or a service call occurs.