Monitoring Printer Environmental Conditions
The following printer environmental conditions can be monitored during generation of
test prints.
The following messages are displayed during test print.
P *** = Number of test prints (unit: sheet)
W*** = Print wait time (unit: sheet)
Pressing the (2) key switches the display. When the (#) key is pressed, the screen exits
the test. (Screen returns to the item 1 condition.)
T =*** = Environment temperature measurement value [unit: °C]
U =*** = Upper heater temperature measurement value. [unit: °C] [###] = target temperature [unit: °C]
H =***% = Environment humidity measurement value [unit: %]
L = *** = Lower thermistor measurement value. [unit: °C] [###] = Lower thermistor AD value [unit: HEX]
Pressing the (2) key switches the display. When the (#) key is pressed, the screen exits
the test. (Screen returns to the item 1 condition.)
KTR, YTR, MTR and CTR are the transfer voltage setting values for each color. (measured in KV)
Pressing the (2) key switches the display. When the (#) key is pressed, the screen exits
the test. (Screen returns to the item 1 condition.)
KR, YR, MR, CR are transfer roller resistance values for each color. [measured in μA]
Pressing the (2) key switches the display. When the (#) key is pressed, the screen exits
the test. (Screen returns to the item 1 condition.)
ETMP: Hopping motor standard speed correction parameter (Environment temperature) [unit: DEC]