0.6 - WARNINGS FOR R290 REFRIGERANT GAS
1. THE APPLIANCE CONTAINS R290 GAS (FLAMMABILITY CLASSIFICATION A3).
2. THE APPLIANCE SHALL BE STORED IN A WELL-VENTILATED AREA WHERE
THE ROOM SIZE CORRESPONDS TO THE ROOM AREA AS SPECIFIED FOR OP-
ERATION.
3. THE APPLIANCE MUST BE INSTALLED, USED AND STORED IN A ROOM WITH A
FLOOR SURFACE HIGHER THAN THE ONE INDICATED IN THE CHART.
Quantity of R290 gas in Kg
(see data label on the appliance)
0,120 0,130 0,140 0,150 0,160 0,170 0,180 0,190 0,200 0,210 0,220
Minimum size of the site
for use and storage (m
2
)
6 7 7 8 8 9 9 10 10 11 11
4. THIS APPLIANCE CONTAINS A QUANTITY OF REFRIGERANT GAS R290 EQUAL
TO THE ONE INDICATED IN THE DATA LABEL LOCATED ON THE APPLIANCE.
5. THE APPLIANCE SHALL BE STORED IN A ROOM WITHOUT CONTINUOUSLY OP-
ERATING IGNITION SOURCES (FOR EXAMPLE: OPEN FLAMES, AN OPERATING
GAS APPLIANCE OR AN OPERATING ELECTRIC HEATER).
6. Do not pierce or burn.
7. Be aware that the refrigerants may not contain an odour.
8. R290 is a refrigerant gas in compliance with the European directives on environment.
Do not pierce any part of the refrigerant circuit.
9. Do not use means to accelerate the defrosting process or to clean, other than those
recommended by the manufacturer.
10. Donotusetoolsdi󰀨erentfromthoserecommendedbythemanufacturerwhende-
frosting and cleaning the appliance.
11. If the appliance is installed, used or stored in a non-ventilated area, the room must
bedesignedtopreventtheaccumulationofrefrigerantleakswiththeconsequentre
or explosion hazard due to the refrigerant combustion caused by electrical heaters,
stoves or others sources of ignition.
12. Compliance with national gas regulations shall be observed.
13. Keep ventilation openings clear of obstruction.
14. The appliance shall be stored so as to prevent mechanical damage from occurring.
15. Any person who is involved with working on or breaking into a refrigerant circuit
shouldholdacurrentvalidcerticatefromanindustry-accreditedassessmentau-
thority, which authorises their competence to handle refrigerants safely in accord-
ancewithanindustryrecognisedassessmentspecication.
16. Servicing shall only be performed as recommended by the equipment manu-
facturer. Maintenance and repair requiring the assistance of other skilled per-
sonnel shall be carried out under the supervision of the person competent in
theuseofammablerefrigerants.
17. TRANSPORT OF EQUIPMENT CONTAINING FLAMMABLE REFRIGERANTS
See transport regulations.
18. MARKING OF EQUIPMENT USING SIGNS
See local regulations.
19. DISPOSAL OF EQUIPMENT USING FLAMMABLE REFRIGERANTS
See national regulations.
20. STORAGE OF EQUIPMENT/APPLIANCES
The storage of equipment should be in accordance with the manufacturer’s instructions.
21. STORAGE OF PACKED (UNSOLD) EQUIPMENT
Storage package protection should be constructed such that mechanical damage to the
equipment inside the package will not cause a leak of the refrigerant charge.