Disassembly and Reassembly ProcedureCLV-180
4-16
ISSUE1
(4) Take off 1 SCREW (CCUK3x6SZ) and take POLE F
and POLE SPACER off together.
Phillips bit (2)
Torque driver
Tightening torque 0.6 Nm
(5) First take off 1 SCREW (CCUK3x4SZ), and adjust
HARNESSand then take off POLE R
Phillips bit (2)
Torque driver
Tightening torque 0.6 Nm
(6) Take off 2 SCREWS (CCUK3x4SZ) and SINK
RETAINER SPRING
Phillips bit (2)
Torque driver
Tightening torque 0.6Nm
(7) Take off 1 SCREW (CCUK3x6SZ) , HARNESS and
DISCHARGE SPRING
Phillips bit (2)
Torque driver
Tightening torque 0.6 Nm
(8) Take off 1 SCREW (CCUK3x6SZ)HARNESS and
DISCHARGE PLATE
Phillips bit (2)
Torque driver
Tightening torque 0.6 Nm
(9) Take off ER2.5SN, DISCHARGE BASE U and
DISCHARGE COIL
Long-nose Pliers
(10) Take off 1 SCREW (CCUK2x4SZ), DISCHARGE
SPINDLE
Phillips bit (2)
Torque driver
Tightening torque 0.6 Nm
(4)
(5) (6)
(8)
CCUK3x6SZ
HARNESS
DISCHARGE
SPRING
(10) ER2.5SN
(9)
CCUK3x6SZ
(11)
CCUK2x4SZ
DISCHARGE
PLATE
DISCHARGE COIL
DISCHARGE
COIL
POLE SPACER