61
Installation
,
O
p
eration and Maintenance Manual ManRE20en Rev.06/2022
OMC S.p.A: Via G. Galilei, 18 - 20060 - Cassina de Pecchi (MI) - ITALY - www.omcvalves.com - Tel.: (+39) 02.95.28.468
LCD display Description
RE20L Model Name
1.0.00
SOFT VER
/
2019MA21
Software Version [SOFT VER] “1.0.00”
Software Input date : “2019 MA 21”
At SOFT VER status if button is pressed, the date will be displayed and then if
button is pressed again, SOFT VER is displayed again.
4.18
RT 0d
Run Time [RT]
Total usage time of the product
Upper “4.18” indicates 4 hours and 18 minutes.
Lower “0d” indicates days used.
Interval to store time is one minute.
3.12
FULL OP
Upward Full Stroke Time [FULL OP]
This value is stored automatically after executing AUTO 2 calibration, and indicates
the time in seconds it takes for the valve to fully open from fully closed.
2.97
FULL CL
Downward Full Stroke Time [FULL CL]
This value is stored automatically after executing AUTO 2 calibration, and indicates
the time in seconds it takes for the valve to fully closed from fully open.
PSNT NCS
Position Sensor Type [PSNT]
Potentiometer [PTN]
Non-Contact Sensor [NCS]
AbS ANGL Absolute Position in Angle [ABS ANGL].