EasyManua.ls Logo

Omron 3G3FV - Input and Output Connections

Omron 3G3FV
33 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5
Input and output connections
The following is a list of the interflite outputs that interface with the inverter: -
Output Description
OP3 Run command
OP6 Multi-step speed reference 3
OP7 Multi-step speed reference 2
OP8 Multi-step speed reference 1
The following is a list of the inverter inputs: -
Terminal Description
1 Down enable
2 Up enable
5 Multi-step speed reference 1
6 Multi-step speed reference 2
7 Multi-step speed reference 3
8 Baseblock (normally closed, when open circuit the transistors are switched off)
11 Supply
7 6 5 Speed Speed Reference
0
0
0
0rpm
d1-01
Frequency ref1
0
0
1
Levelling speed
d1-02
Frequency ref2
0
1
0
0rpm
d1-03
Frequency ref3
0
1
1
Test speed
d1-04
Frequency ref4
1
0
0
0rpm
d1-05
Frequency ref5
1
0
1
High speed
d1-06
Frequency ref6
1
1
0
0rpm
d1-07
Frequency ref7
1
1
1
0rpm
d1-08
Frequency ref8
SECTION D
Control panel

Related product manuals