4. UPS functions
31
Thisfunctionnoties you with LEDdisplayand beep sound whenthebatteryneeds to be replaced.
The battery life counter operates while commercial power is supplied after shipment. (When the ambi-
ent temperature of the battery is higher than 25°C, the value of the counter will be incremented at a
faster pace.)
When the battery needs to be replaced, the battery replacement lamp will light up and beep will sound.
* Be sure to reset the battery life counter after replacing the battery.
Resetting can be performed with “Control” - “Reset B.life counter” in the menu on the LCD.
4-3
Battery life counter function
4-4
LCD menu items
A list of menu items on the LCD is shown in the table below. Menu items displayed vary depending on
the menu type setting. The menu type can be set with "Setting" - "Local Setting" - "Menu Type". There
are two types of menu: "Standard" (for general users) and "Advanced" (for administrators).
: Displayed only when the menu type is "Advanced". (Not displayed in "Standard".)
☆
: Displayed only when the UPS is stopped. (Not displayed during operation.)
Menu Description
Measurements Load Meter Display the applied load in VA and W.
Input/Output Meter Display the input/output voltage and
frequency.
Battery Meter Display the status of the built-in battery.
Longevity Display the estimated lifespan of the
UPS in 5 levels.
Cumulat. Power Usage Display the amount of power used so
far and the number of days elapsed.
Average Power Display the average amount of power
used so far.
Control Start Function Test Perform a self-diagnosis and a test to
check for battery deterioration, and
then display the results.
Reset B.life counter Reset the battery life counter.
Load Segments Control the ON/OFF of output
receptacle group B and C.
Reset Power Usage Reset the values of cumulative power
usage and average power usage.
Dry Contact Test
☆
Perform a contact test when using a
contact signal card (SC07/SC08).
Initialization
☆
Return each of the UPS settings to the
factory settings.
Maintenance Bypass Move to Bypass Mode forcibly.